Concrete Guides
Concrete Guides
Cost, mix design, pouring and curing, slabs, footings and reinforcement, explained with worked numbers.
All guides
Page 3 of 5
Mix & Materials Air Entrainment in Concrete: When and Where You Actually Need It When to use air-entrained concrete and when not to: by project and US climate, target air of 5–7.5% by stone size, how the admixture is dosed and why hard-troweled floors get none.
Mix & Materials Concrete Pigments: How to Calculate Color Dosage Accurately Dose concrete pigment as a % of cement weight: 1–6% for most colours, saturation near 5–6 lb per sack, 10% maximum under ASTM C979. Worked examples per yd³, m³ and per bag.
Structural & Reinforcement Concrete Footing Depth: Frost Line, Soil Type & Building Codes How deep a concrete footing must be: below the local frost line and at least 12 in under undisturbed ground (IRC), 42–60 in in Minnesota, 450 mm in the UK. Width from soil bearing, worked examples.
Mix & Materials Fiber Reinforcement vs Rebar: A Real-World Comparison Microfibers (0.5–1.5 lb/yd³) control plastic shrinkage cracks; macro fibers (3–15 lb/yd³) can be engineered to replace mesh or light rebar in slabs. Rebar still carries structural loads.
Structural & Reinforcement Rebar Spacing Guide: ACI 318 vs Eurocode 2 vs BS 8110 Rules Minimum and maximum rebar spacing under ACI 318, Eurocode 2 and BS 8110 side by side, with slab examples: 18 in max for a 4-inch slab, 400 mm main bars in EC2, and clear vs centre spacing.
Structural & Reinforcement Wire Mesh vs Rebar: Load Capacity Compared Wire mesh vs rebar in slabs: 6×6 W1.4 mesh gives 0.028 in² of steel per foot, #3 rebar at 18 in gives 0.073 and #4 at 12 in 0.20. What each does to load capacity, cracks and placement.
Structural & Reinforcement How Thick Should a Concrete Slab Be? Global Guide by Use Case Concrete slab thickness by use: 3.5 in IRC minimum for house floors, 4 in for patios, walks and car driveways, 5–6 in for trucks and RVs, 6 in+ for warehouses. Tables, load math and base.
Structural & Reinforcement Anchor Bolt and Embed Plate Design: The Basics How ACI 318 checks anchor bolts: steel, breakout, pullout and edges, with minimum embedment depth by bolt size (1/2 to 1-1/2 in, M12 to M36) and a worked embed plate design example.
Structural & Reinforcement Concrete Beam Sizing for Residential Projects Size a house concrete beam: depth of span ÷ 10–12, ACI minimums, a worked 5 m example (moment, steel, stirrups), a span table from 3 to 7.5 m and the deflection limits.
Structural & Reinforcement How Much Weight Can a Concrete Slab Hold? A 4-inch slab on good ground safely takes about 2,300–2,800 lb on one wheel or post away from the edges; 6 inches takes about 4,800–5,800 lb. Worked method, tables and edge rules.
Pouring, Curing & Finishing Concrete Expansion Joints: Spacing Rules for Every Slab Type Control joints go every 24–36 times the slab thickness (8–12 ft for a 4-inch slab, 15 ft max). Expansion joints go at walls, columns and old slabs. Tables for every slab type.
Pouring, Curing & Finishing How Long Does Concrete Take to Cure? Full Timeline by Climate Walk on new concrete after 24 hours, drive a car on it after about 7 days, trucks after 28. Keep it moist 3–7 days and above 50°F; cold weather can triple the wait. Full timeline.