Your building department has the final number. Frost depth is set locally and printed in the jurisdiction's climate table. Check it, and any amendments, before digging. Structural footings for unusual loads or soils need an engineer.
The two things that set footing depth
A footing has to satisfy two separate depth requirements, and the deeper one governs:
- 1
Below the frost line
Soil that freezes can heave. The bottom of the footing must sit below the depth to which the ground freezes in your area, or the foundation must be protected from frost another way.
- 2
On good bearing soil
The footing must rest on undisturbed natural soil, below topsoil, organic material and loose fill, that can carry the load without settling. Under the IRC that is never less than 12 inches below the ground surface.
In cold climates the frost line usually governs. In warm climates the bearing requirement and the 12-inch minimum govern, and on expansive clay the depth needed to get below seasonal moisture change can govern instead.
How the codes handle frost
The IRC does not print one national frost depth. Each jurisdiction enters its frost line depth in Table R301.2(1), and section R403.1.4.1 says foundations must be protected from frost by one of four methods:
| Method | What it means |
|---|---|
| Extend below the frost line | The usual approach: dig to the local frost depth |
| Frost-protected shallow foundation (R403.3) | Rigid insulation keeps the ground under a heated building from freezing, so footings can be shallow |
| Design to ASCE 32 | The engineering standard behind frost-protected shallow foundations |
| Bear on solid rock | Rock does not heave |
The model code also says footings must never bear on frozen soil unless it is permanently frozen.
Real frost depths: Minnesota as an example
Minnesota writes its frost depths into state rule, by county:
| Zone | Minimum footing depth | Example counties |
|---|---|---|
| Zone I (north) | 60 in (5 ft) | St. Louis (Duluth), Clay (Moorhead), Beltrami, Itasca, Otter Tail |
| Zone II (south) | 42 in (3 ft 6 in) | Hennepin and Ramsey (Twin Cities), Dakota, Olmsted (Rochester), Stearns |
The rule allows less depth only with supporting evidence from an engineer competent in soil mechanics. Other cold states and cities set their own values; mild-climate jurisdictions may list only a few inches, in which case the 12-inch minimum takes over.
Exceptions in the model code
| Structure | Frost protection required? |
|---|---|
| Freestanding accessory building, light-frame, ≤ 600 sq ft, eave ≤ 10 ft | No (still 12 in minimum) |
| Freestanding accessory building, other construction, ≤ 400 sq ft, eave ≤ 10 ft | No |
| Deck not supported by the dwelling | No, in the model text |
| Deck attached to the house | Yes |
| House, attached garage, porch footings | Yes |
Many jurisdictions amend these exceptions, so treat the table as the starting point. Minnesota, for instance, additionally allows slab-on-grade foundations for detached one-storey garages, carports and sheds up to 3,000 sq ft.
Frost in the UK
In England and Wales, strip foundations are taken to at least 450 mm below ground for frost, unless bearing on rock, and to about 1 m on high-shrinkage clay, where seasonal shrinking and swelling is the bigger risk. Near trees on clay, deeper foundations are needed and are set by the NHBC and the building control body.
Soil bearing and footing width
Once the depth is set, the footing must be wide enough that the soil is not overstressed. Without a soils report, the IRC allows these presumptive values:
| Soil (IRC Table R401.4.1) | Presumptive bearing |
|---|---|
| Crystalline bedrock | 12,000 psf |
| Sandy gravel and gravel (GW, GP) | 3,000 psf |
| Sand, silty sand, clayey sand, silty and clayey gravel (SW, SP, SM, SC, GM, GC) | 2,000 psf |
| Clay, sandy clay, silty clay, clayey silt, silt, sandy silt (CL, ML, MH, CH) | 1,500 psf |
If the building official suspects soil weaker than 1,500 psf, a soils investigation is required. Peat, organic soil and uncompacted fill are never acceptable bearing.
3,000 lb/ft ÷ 1,500 psf = 2.0 ft (24 in)
Column pad area = column load ÷ allowable bearing
30,000 lb ÷ 1,500 psf = 20 ft² → 4 ft 6 in × 4 ft 6 in (20.25 ft²)
For ordinary houses the IRC tabulates minimum widths directly:
| Construction (IRC Table R403.1) | 1,500 psf | 2,000 psf | 3,000 psf | ≥ 4,000 psf |
|---|---|---|---|---|
| Light frame, 1 storey | 12 in | 12 in | 12 in | 12 in |
| Light frame, 2 storey | 15 in | 12 in | 12 in | 12 in |
| Light frame, 3 storey | 23 in | 17 in | 12 in | 12 in |
| Brick veneer or 8 in hollow block, 1 storey | 12 in | 12 in | 12 in | 12 in |
| Brick veneer or 8 in hollow block, 2 storey | 21 in | 16 in | 12 in | 12 in |
| 8 in solid or grouted masonry, 2 storey | 29 in | 21 in | 14 in | 12 in |
Spread footings must be at least 6 inches thick, with a projection beyond the wall of at least 2 inches and not more than the footing thickness. Check the edition your jurisdiction has adopted; table values have changed between editions.
Soil that heaves
Frost heave needs three things: freezing temperatures, a frost-susceptible soil and water. Silts and fine silty sands are the worst, because they draw water up to the freezing zone and grow ice lenses. Clean gravel and coarse sand drain freely and heave little. Good drainage around the footing, and keeping roof water away from the foundation, reduces the risk on any soil.
Working out the concrete for the footing
Strip footing
100 ft perimeter, 20 in wide × 8 in thick.
100 × 1.667 × 0.667 = 111 ft³ ÷ 27
≈ 4.1 yd³ (+5–10% waste)
Column pad
4 ft 6 in × 4 ft 6 in × 12 in thick.
4.5 × 4.5 × 1.0 = 20.25 ft³ ÷ 27
0.75 yd³ per pad
Deck pier, 10 in tube
42 in deep: π × (5 ÷ 12)² × 3.5 = 1.91 ft³
≈ 0.07 yd³ per post, about 3.2 bags of 80 lb mix (0.60 ft³ each)
The Concrete Footing Calculator does strip and pad footings; the Sonotube Calculator and Post Hole Calculator handle round piers.
Common footing depth mistakes
- Using a national map instead of the local number. Frost depth is a local code value and may be deeper than any average map shows.
- Measuring from finished grade that is not there yet. Depth is measured from the final ground surface. Lowering the grade later, for a patio or driveway, can leave footings too shallow.
- Bearing on fill or topsoil. The bottom must be undisturbed natural soil; over-dug trenches are filled with concrete, not loose soil.
- Shallow deck and porch footings. Attached decks and porches need the same frost depth as the house in most jurisdictions.
- Pouring on frozen ground. Footings may not bear on frozen soil; protect the trench and the fresh concrete from freezing in winter.
- Undersizing column pads. A 12 in wide footing under a 30,000 lb column on clay would load the soil far beyond 1,500 psf. Size the area from the load.
The bottom line
Get the frost depth from your building department, go at least that deep and never less than 12 inches below undisturbed ground, and size the width from the soil's bearing value. In the UK plan on at least 450 mm, and about 1 m on shrinkable clay. Look up your depth with the Frost Depth / Footing Depth Calculator, then size and price the concrete with the Concrete Footing Calculator.