📖 Glossary

How to Calculate Concrete for a Slab: The Complete Step-by-Step Guide (2026)

The whole process in eight steps: the formula, choosing thickness, measuring odd shapes, waste, bags or ready-mix, strength, reinforcement and base, with a worked example and ready-made tables.

Updated 4 min read 4 sources cited
Square slab formed with timber boards, gravel base and a tape measure laid across it
The short answer

Multiply length × width × thickness in the same unit. In feet and inches: length (ft) × width (ft) × thickness (in) ÷ 12 ÷ 27 = cubic yards. A 12 × 12 ft slab at 4 in is 1.78 yd³, or 80 bags of 80 lb mix (0.60 ft³ each). In metric: length (m) × width (m) × thickness (mm) ÷ 1000 = m³, so a 3 × 4 m slab at 100 mm is 1.2 m³. Add 5–10% for waste and an uneven base, and order ready-mix for anything above a cubic yard or two.

÷ 27cubic feet to cubic yards
1.78 yd³12 × 12 ft slab at 4 in
+5–10%waste allowance to add
On this page
  1. Step 1: The formula
  2. Step 2: Choose the thickness
  3. Step 3: Measure the area
  4. Step 4: Add waste
  5. Step 5: Bags or ready-mix
  6. Step 6: Choose the strength
  7. Step 7: Reinforcement and joints
  8. Step 8: Prepare the base
  9. Putting it together: a 12 × 20 ft shed slab
  10. Common mistakes
  11. The bottom line

Step 1: The formula

ImperialCubic yards = length (ft) × width (ft) × thickness (in) ÷ 12 ÷ 27
12 × 12 × 4 ÷ 12 ÷ 27 = 1.78 yd³
MetricCubic metres = length (m) × width (m) × thickness (mm) ÷ 1000
3 × 4 × 100 ÷ 1000 = 1.2 m³

Divide inches by 12 to get feet, and cubic feet by 27 to get cubic yards. One cubic yard is 27 ft³ or 0.765 m³.

Step 2: Choose the thickness

ProjectTypical thickness
Interior floor slab (IRC minimum)3.5 in, 4 in common
Walkway or sidewalk4 in
Patio4 in (5 under a hot tub)
Shed or equipment pad4 in; more for heavy equipment
Garage floor4–5 in
Driveway, cars4 in
Driveway, trucks and RVs5–6 in

More detail in our slab thickness guide.

Step 3: Measure the area

  • Rectangles: length × width, measured inside the forms.
  • L-shapes: split into two rectangles and add them.
  • Triangles: ½ × base × height.
  • Circles: π × radius². A 10 ft round slab is 78.5 sq ft.
  • Thickened edges: add the edge as its own strip (width × extra depth × perimeter).
  • Uneven base: measure depth at several points and use the average.

The Multi-Shape Volume Calculator adds sections for you.

Step 4: Add waste

Add 5% for a compacted, level base and straight forms; up to 10% for uneven ground, curves, a pump or a first-time pour. Running short means a second truck and often a short-load fee. Fine-tune with the Waste Factor Calculator.

Step 5: Bags or ready-mix

Slab at 4 inVolumeWith 10%80 lb bags60 lb bags
10 × 10 ft1.23 yd³1.36 yd³5675
10 × 12 ft1.48 yd³1.63 yd³6789
12 × 12 ft1.78 yd³1.96 yd³80107
12 × 20 ft2.96 yd³3.26 yd³134178
20 × 20 ft4.94 yd³5.43 yd³223297
24 × 24 ft7.11 yd³7.82 yd³320427

Bag counts before waste. One cubic yard is 45 bags of 80 lb mix, so bags only make sense for small pads; compare in bags vs ready-mix or with the Bags Calculator.

Step 6: Choose the strength

SlabIRC minimum
Interior slabs and basement floors2,500 psi
Garage floors and exposed exterior slabs, severe weathering3,500 psi, 5–7% air

For freeze-thaw exposure always specify air-entrained concrete; see concrete grades and air entrainment.

Step 7: Reinforcement and joints

Reinforcement does not stop cracks; it keeps them tight. Typical options are wire mesh or #3–#4 rebar on chairs in the upper part of the slab, or fibres (see wire mesh vs rebar and fiber vs rebar). Either way, plan control joints at 24–36 × the slab thickness: 8–12 ft for a 4 in slab.

Step 8: Prepare the base

  1. 1

    Strip and dig

    Remove topsoil and organic material down to firm ground.

  2. 2

    Base course

    4 in of compacted gravel or crushed stone (the IRC requires a base course under floor slabs, with exceptions for well-drained sand and gravel soils).

  3. 3

    Vapour retarder

    Under heated interior slabs.

  4. 4

    Forms

    Set to line and level, sloped for drainage outdoors.

Putting it together: a 12 × 20 ft shed slab

Volume

12 × 20 × 4 ÷ 12 ÷ 27

2.96 yd³

Waste

2.96 × 1.10

Order 3.25 yd³

Base

12 × 20 × 4 in of gravel

2.96 yd³ compacted

At 147 bags of 80 lb mix with waste, this is a ready-mix job. Check the supplier's small-load threshold before ordering.

Common mistakes

  • Forgetting to divide inches by 12, or cubic feet by 27.
  • Using nominal form depth when the base is low in places.
  • No waste allowance.
  • Ordering bags for a multi-yard slab.
  • Skipping joints and getting random cracks.

The bottom line

Volume = length × width × thickness: in imperial, ft × ft × in ÷ 12 ÷ 27; in metric, m × m × mm ÷ 1000. A 12 × 12 ft slab at 4 in is 1.78 yd³. Add 5–10%, use ready-mix above a yard or two, and plan the strength, reinforcement, joints and base. Get your numbers from the Slab Calculator.

Frequently asked questions

How do I calculate cubic yards for a slab?

Multiply length × width in feet × thickness in inches, divide by 12 to get cubic feet, then divide by 27. A 20 × 20 ft slab at 4 in: 20 × 20 × 4 ÷ 12 = 133.3 ft³ ÷ 27 = 4.94 yd³.

How many bags of concrete for a 10 × 10 slab?

At 4 in thick it is 33.3 ft³, so 56 bags of 80 lb mix (0.60 ft³ each) or 75 bags of 60 lb mix (0.45 ft³), before waste. That volume, 1.23 yd³, is often cheaper and easier as a small ready-mix or mixer-truck delivery.

How thick should a slab be?

3.5–4 in for interior floors, walks, patios and sheds, 4–5 in for garage floors and car driveways, 5–6 in for heavy vehicles, RVs and equipment pads. See our slab thickness guide for details.

How do I calculate a round slab?

Area = π × radius². A 10 ft diameter slab (radius 5 ft) is 3.1416 × 25 = 78.5 sq ft; at 4 in that is 26.2 ft³ or 0.97 yd³.

How much extra concrete should I order?

5% for a well-compacted base and straight forms, up to 10% for uneven ground, curves or a pump. It is cheaper than a second truck.

What strength concrete do I need for a slab?

Under the IRC, interior slabs need at least 2,500 psi; garage floors and exposed exterior slabs in severe weathering regions need 3,500 psi with 5–7% air entrainment. Driveways are commonly ordered at that strength or higher; ask your supplier for an exterior flatwork mix.

Sources and author

Bag yields are from the manufacturer's data sheet; strength and air rules from a city summary of IRC Table R402.2; slab and base minimums from IRC R506; joint spacing from NRMCA. All volumes are calculated in the text.

  1. QUIKRETE Concrete Mix No. 1101 data sheet. yield 0.30 ft³ (40 lb), 0.45 ft³ (60 lb), 0.60 ft³ (80 lb)
  2. City of Grand Rapids, MN, Concrete slabs handout (IRC Table R402.2). 2,500 psi interior slabs; 3,500 psi and 5–7% air for garage floors and exposed slabs in severe weathering
  3. California Residential Code (IRC model text), Section R506. 3.5 in minimum floor slab, 4 in base course, vapour retarder
  4. NRMCA, CIP 6: Joints in concrete slabs on grade. joint spacing 24–36 × thickness
Rachel Sousa
Technical Writer & Content Lead · B.S. Civil Engineering, Purdue

Rachel holds a B.S. in Civil Engineering from Purdue University and spent 10+ years turning construction and engineering standards into clear documentation, including as documentation lead at a national ready-mix supplier. She writes every guide and calculator page on AllConcreteCalculator.com and owns the site’s editorial standards.

Published · Last updated · @rachelsousa101